Bollards
Bollards
Product instruction
Hydraulic or pneumatic terminal for protection against any intrusion by vehicles. Safety guaranteed even with ONLY one terminal. For hydraulic terminals, an independent hydraulic pump is designed, access for simplified maintenance, burglar protection sensor (optional)
OAK 1200.12
Anti-terrorism hydraulic automatic bollard. Subject to a crash test and certified by an accredited third party laboratory according to IWA 14-1: 2013 V / 7200 [N3C] / 80/90, equivalent to PAS68: 2010 7500/80 / N3 and ASTM2656: 2007 M50 (ex K12 , Only one terminal). Corresponding to the European machine directive / European Low Voltage Directive / European EMC directive. Dimensions of the rod driven above ground: Ø330 x h. 1,200 mm (± 3 mm) x thickness 25 mm Steel Fe 510 (S335JR). Crash resistance: 2 100 00 J. standard rise time: ≤5.3s and fall time: 4.0s. IP67. Ambient working temperature up to -40 ° C + 60 ° C. Power supply: 1-phase 230 Vac ± 10%, 50-60 Hz. Control unit compatible with TCP / IP and RS485. Max 2 terminals for each control unit. Parallel control wiring, possibility of controlling many groups of terminals. Power consumption 1.55kW for each terminal. The terminal remains at the top even in the event of a power failure. It is possible to lower the terminal by specific means. Independent hydraulic pump for each terminal: In the event of a pump failure, the other terminals continue to operate. Easy access to the hydraulic pump for simplified service with an anti-sabotage switch.
OAK 800.4
Anti-terrorism hydraulic automatic bollard. K4 counterterrorism terminal equivalent, based on dynamic simulation performed by a third party Laboratory accredited to international standards ASTM2656: 2007 M30 – PAS68: 2010 7500/50 / N2. Protection guaranteed even with a terminal. Dimensions of the rod driven above ground: Ø280 x h.800 mm x th.10 mm, in Fe 510 steel (S335JR). Crash resistance: 667 000 00 J. standard rise time: ≤7.0s and fall time: 4.0s. IP67. Ambient working temperature up to -40 ° C + 60 ° C. Power supply: 1-phase 230 Vac ± 10%, 50-60 Hz. Control unit compatible with TCP / IP and RS485. Max 4 terminals for each control unit. Parallel control wiring, possibility of controlling many groups of terminals. Power consumption 0.55kW for each terminal. Independent hydraulic pump for each terminal: In the event of a pump failure, the other terminals continue to operate. Easy access to the hydraulic pump for simplified service. Obstacle detection, configurable (with / without motion reversal). Available in two versions:
1) Standard : the terminal opens even on power failure
2) Security : the terminal will remain high even on a power failure. It is possible to lower the bollard using a mechanical security key. Lower the terminal by means of a solenoid valve which is accessible from the floor flange.